Hypercool Air-Cooled Aftercoolers

Hypercool Air-Cooled Aftercoolers

Highly efficient air cooled aftercoolers for the removal of water vapour and cooling of compressed air downstream from compressors and blowers.

ADS/ADT. Available on backorder . . Brand:

Description

Highly efficient air cooled after coolers. The Hypercool range represents a cost effective solution to easily remove water vapour and cool compressed air to safe usable levels for many industrial applications.

ADT coolers can be used when cooling water is not available, limiting costs and plant complexity and can prepare the air for further filtration and drying. Hypercool coolers can be installed immediately downstream of compressors or blowers in order to remove up to 80% of the condensate, protecting the entire compressed air system or production process.

A high quality aftercooler, properly sized is an excellent investment that can help ensure that the compressed air system works efficiently, thereby guaranteeing the quality of the finished product.

The Parker Hiross Hypercool range of air cooled aftercoolers represents a cost effective solution to easily remove water vapour from compressed air and cool it to safe usable levels for many industrial applications.

Hypercool air cooled aftercoolers can be used when cooling water is not available, limiting costs and plant complexity and will prepare the air for further filtration and drying. The aftercoolers can be installed immediately downstream of compressors or blowers in order to remove up to 80% of the condensate, protecting the entire compressed air system or production process.

A high quality aftercooler, properly sized is an excellent investment that can help ensure that the compressed air system works efficiently, thereby guaranteeing the quality of the finished product.

Features

  • Robust construction and compact design
  • Low pressure drop design
  • Protective grill for fan and heat exchanger
  • High efficiency and low noise axial fans
  • Standard protection with epoxy powder coating
  • Full range of matching centrifugal separators “Hypersep”
  • Extensive range of condensate drains “Hyperdrain”

Benefits

  • Significant energy and capital investment savings
  • Optimised compressed air systems performance
  • Reduced maintenance and improved product quality
  • Reliability and continuous operation
  • Very low pressure drops with optimum cooling performances

For more information or a detailed discussion about your specific requirements please contact Parker or an authorised Parker distributor.

Philosophy

Parker Hiross specializes in cooling, purification, and separation technologies, where compressed air and gas purity, product quality, technological excellence and global support are paramount. We design and manufacture compressed air treatment products and cooling equipment for many key industries where ease of integration, low cost of ownership and energy saving can make the difference. 

Parker Hiross has been supplying industry with high efficiency products with low lifetime costs and reduced CO2 emissions since 1964. Our philosophy ‘to stand out from the crowd’ is our credo, encouraging our employees to achieve continuous improvement and satisfy customer expectations.

  • Robust construction and compact design
  • Standard protection with epoxy powder coating
  • Low pressure drop design
  • Stainless steel rivets and screws
  • Protective grill for fan and heat exchanger
  • Full range of matching centrifugal separators “Hypersep”
  • High efficiency and low noise axial fans
  • Legs or support plate available on request for smaller models
  • Extensive range of condensate drains “Hyperdrain”

Operation:

  • Hot compressed air passes through the ADT copper tubes.
  • Ambient air is forced across these externally finned tubes by the use of an axial fan.
  • Compressed air is cooled to a temperature which can be as little as 10 °C above the ambient temperature.
  • As the compressed air cools down, up to 80% of the water vapour condenses to a liquid and this is efficiently removed by a centrifugal separator installed at the ADT outlet.

Versions:

  • ADT with Low Pressure drop (LP version) for low operating pressure;
  • ADT with Low Noise fan motor (LN version)
  • ADP version with pneumatic motor
  • Legs and support plate kit for smaller models
  • Counterflanges kit
  • ADT with copper fins and tubes for marine environments avilable on request
  • Epoxy coating on all exposed copper as protection in aggressive environments

Applications:

  • Compressed air cooling and dehumidification
  • Pneumatic transportation
  • Cooling air before an adsorption dryer
  • Glassware-industry
  • Railway and transportation industry

Available with pneumatic motor for installations where electrical power is either not available or not recommended.

How can we help you?

Thank you for your interest in our product. Please fill out the form below and we will get back to you as soon as possible.